Siemens A07401 fault code meaning

Siemens / A07401

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, S120-S150

Drive: Maximum DC bus voltage controller disabled

converter

Meaning: The Vdc_max controller cannot keep the DC bus voltage (r0070) below the limit values (r1242, r1282) and is therefore disabled. - The input voltage remains above the voltage specified for the power unit. - During regenerative operation, the motor is continuously driven by the load.

Possible causes

Source: SINAMICS G110M P707; SINAMICS G115D P765; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P736; SINAMICS G120, Control Unit CU250S-2 P1371; SINAMICS G120C P681; SINAMICS S120_S150 P2744

Series: G120X, G120XA

Drive: Maximum DC bus voltage controller disabled

converter

Meaning: The Vdc_max controller cannot keep the DC bus voltage (r0070) below the limit (r1242, r1282) and is therefore disabled. - The input voltage remains higher than the voltage specified for the power unit. - During regenerative operation, the motor is continuously driven by the load.

Possible causes

Source: SINAMICS G120X Converter P1379; SINAMICS G120XA PN Converter P1289

Series: G130-G150

Drive: DC link voltage maximum controller de-activ

converter

Meaning:

Possible causes

Source: G150 P862

Series: G200, G210, G210X, G220

Drive: Maximum DC bus voltage controller disabled

converter

Meaning: The Vdc_max controller cannot keep the DC bus voltage (r0070) below the limits (r1242, r1282) and therefore disables itself. - The mains voltage remains above the voltage specified for the power unit. - During regenerative operation, the motor is continuously driven by the load.

Possible causes

Source: SINAMICS G200 Converter P709; SINAMICS G210 Converter P1106; SINAMICS G210X Converter P968; SINAMICS G220 Converter P1323

Series: S220

Drive: Maximum DC bus voltage controller disabled

converter

Meaning:

Possible causes

Source: SINAMICS S220 Converter P2279