Siemens A07400 fault code meaning

Siemens / A07400

Series: G110M, G210X

Drive: Maximum DC bus voltage controller active

converter

Meaning:

Possible causes

Source: SINAMICS G110M P706; SINAMICS G210X Converter P967

Series: G115D

Drive: Maximum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the upper activation threshold (r1242, r1282) was exceeded. The ramp-down time is automatically increased to keep the DC bus voltage (r0070) within the permissible limits. A control deviation exists between the speed setting and the actual speed. Therefore, when the DC bus voltage controller is deactivated, the ramp-function generator output is set to the speed setpoint. See also: r0056 (Closed-loop control status word), p1240 (Vdc controller configuration (vector control)), p1280 (Vdc control or Vdc monitoring configuration (V/f)).

Possible causes

Source: SINAMICS G115D P765

Series: G120-CU230P-2

Maximum intermediate circuit voltage controller active

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P493

Series: G120-CU240B-E-2, G120-CU250S-2

Drive: Maximum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the upper activation threshold (r1242, r1282) was exceeded. The ramp-down time is automatically increased to keep the DC bus voltage (r0070) within the permitted limits. A control deviation exists between the speed setting and the actual speed. Therefore, when the DC bus voltage controller is disabled, the ramp-function generator output is set to the speed list value. See: r0056 (Closed-loop control status word), p1240 (Vdc Controller configuration (vector control)), p1280 (Vdc Controller configuration (V/f))

Possible causes

Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P736; SINAMICS G120, Control Unit CU250S-2 P970

Series: G120C

Drive: Maximum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller was activated because the upper activation threshold (r1242, r1282) was exceeded. The ramp-down time is increased automatically to keep the DC bus voltage (r0070) within the permissible limits. A control deviation exists between the speed reference and the actual speed. Therefore, when the DC bus voltage controller is disabled, the ramp-function generator output is set to the speed list value. See also: r0056 (Closed-loop control status word), p1240 (Vdc controller configuration (vector control)), p1280 (Vdc controller configuration (V/f))

Possible causes

Source: SINAMICS G120C P680

Series: G120D

VDC_max controller takes effect

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120D with Control Unit CU250D-2 P323

Series: G120P-Cabinet

The maximum controller for the DC-link voltage

converter

Meaning:

Possible causes

Source: SINAMICS G120P Cabinet P511

Series: G120X, G120XA

Drive: Maximum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller is activated because the upper activation threshold (r1242, r1282) has been exceeded. The ramp-down time is automatically increased to keep the DC bus voltage (r0070) within the permissible limits. A control deviation exists between the speed setting and the actual speed. Therefore, when the DC bus voltage controller is deactivated, the ramp-function generator output is set to the speed setpoint. See also: r0056, p1240, p1280

Possible causes

Source: SINAMICS G120X Converter P1379; SINAMICS G120XA PN Converter P1289

Series: G130-G150

Drive: DC link voltage maximum controller active

converter

Meaning:

Possible causes

Source: G150 P862

Series: G200, G210, G220, S220

Drive: Maximum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller was activated because the upper activation threshold (r1242, r1282) was exceeded. The ramp-down time is automatically increased to keep the DC bus voltage (r0070) within the permissible limits. A control deviation exists between the speed setpoint and the actual speed. Therefore, when the DC bus voltage controller is disabled, the ramp-function generator output is set to the actual speed. Once the condition has persisted beyond the standstill detection waiting time p1227, the converter automatically enters pulse inhibit (OFF2). See also: r0056 (closed-loop control status word), p1240 (Vdc control or Vdc monitoring configuration), p1280 (Vdc control or Vdc monitoring configuration (V/f))

Possible causes

Source: SINAMICS G200 Converter P709; SINAMICS G210 Converter P1106; SINAMICS G220 Converter P1323; SINAMICS S220 Converter P2279

Series: S110

Drive: Maximum DC bus voltage controller active

servo drive

Meaning: The DC bus voltage controller was activated because the upper activation threshold (p1244) was exceeded. This results in a control deviation between the reference speed and the actual speed. See: r0056 (Closed-loop control status word), p1240 (Vdc control or Vdc monitoring configuration).

Possible causes

Source: SINAMICS S110 P1010

Series: S120-S150

Drive: Maximum DC bus voltage controller active

converter

Meaning: The DC bus voltage controller has been activated because the upper activation threshold (r1242, r1282) was exceeded. The ramp-down time is automatically increased to keep the DC bus voltage (r0070) within the permissible limits. A control deviation exists between the speed setpoint and the actual speed. Therefore, when the DC bus voltage controller is disabled, the ramp-function generator output is set to the speed list value. See also: r0056 (Closed-loop control status word), p1240 (Vdc control or Vdc monitoring configuration), p1280 (Vdc control or Vdc monitoring configuration (V/f)).

Possible causes

Source: SINAMICS S120_S150 P2744