Siemens A07352 fault code meaning

Siemens / A07352

Series: G110M, G120-CU250S-2, G120C, G120D

Drive: Implausible limit switch signal

converter

Meaning: The limit switch signals are implausible. Possible causes: - Incorrect interconnection of BICO (p3342, p3343). - The sensors provide invalid signals (both provide a 0 signal).

Possible causes

Source: SINAMICS G110M P706; SINAMICS G120 Control Units CU250S-2 P1062; SINAMICS G120C P680; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P870

Series: G115D

Drive: Implausible stop sensor

converter

Meaning: The stop sensors are implausible. Possible causes: - Incorrect interconnection of BICO (p3384, p3385, p3386). - The sensors provide invalid signals (both provide a 0 signal or a 1 signal).

Possible causes

Source: SINAMICS G115D P764

Series: G120-CU240B-E-2

Drive: Implausible limit switch signal

converter

Meaning:

Possible causes

Source: SINAMICS G120 Control Unit CU240B- 2_CU240E- 2 P841

Series: G120X, G120XA

Drive: Implausible limit switch signal

converter

Meaning: The limit switch signals are implausible. Possible causes: - Incorrect interconnection of BICO (p3342, p3343). - The encoders provide invalid signals (both provide the 0 signal).

Possible causes

Source: SINAMICS G120X Converter P1378; SINAMICS G120XA PN Converter P1288