Siemens A07329 fault code meaning
Siemens / A07329
Series: G120-CU250S-2
Drive: kT evaluator, kT(iq) characteristic curve or voltage compensation failure
converter
Meaning: A function of the "Extended torque control" function module (r0108.1) has been activated, but it has not taken full effect.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1369
Series: S120-S150
Drive: kT evaluator, kT(iq) characteristic curve or voltage compensation failure
converter
Meaning:
Possible causes
Source: SINAMICS S120_S150 P2738
Series: S220
Drive: kT adapter, kT(iq) characteristic curve or voltage compensation failure
converter
Meaning: Extended torque control is not fully supported.
Possible causes
Source: SINAMICS S220 Converter P2272