Siemens A05006 fault code meaning
Siemens / A05006
Series: G110M, G120-CU240B-E-2, G120-CU250S-2
Power unit: Thermal model overheat
converter
Meaning: The temperature difference between the chip and the heatsink has exceeded the permissible limit (modular power units only). The corresponding overload response is executed according to p0290. See: r0037 (Power unit temperature)
Possible causes
Source: SINAMICS G110M P699; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P730; SINAMICS G120, Control Unit CU250S-2 P1357
Series: G115D, G120C
Power unit: Thermal model overheat
converter
Meaning: The temperature difference between the chip and the heatsink has exceeded the permissible limit (only for modular power units). The corresponding overload response is executed according to p0290. See also: r0037 (Power unit temperature).
Possible causes
Source: SINAMICS G115D P756; SINAMICS G120C P673
Series: G120-CU230P-2, G120P-Cabinet
Power module overheat
converter
Meaning:
Possible causes
Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P491; SINAMICS G120P Cabinet P510
Series: G120D
"Overtemperature thermal model"
converter
Meaning:
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P791
Series: G120X, G120XA, G130-G150
Power unit: Thermal model overheat
converter
Meaning: The temperature difference between the chip and the heatsink has exceeded the permissible limit (modular power units only). The corresponding overload response is executed according to p0290. See also: r0037
Possible causes
Source: SINAMICS G120X Converter P1370; SINAMICS G120XA PN Converter P1281; SINAMICS G130_G150 P1584
Series: S110
Power unit: Thermal model overheat
servo drive
Meaning: The temperature difference between the chip and the heatsink has exceeded the permissible limit (modular power units only). The corresponding overload reaction is performed according to p0290. See: r0037.
Possible causes
Source: SINAMICS S110 P1004
Series: S210
Power unit: Thermal model overheat
servo drive
Meaning: The temperature difference between the chip and the heatsink has exceeded the permissible limit (modular power units only). The corresponding overload response is performed according to p0290. See also: r0037 (drive temperature). Faults and alarms 18.2 List of faults and alarms SINAMICS S210 servo drive system with S-1FK2 and S-1FT2 882 Operating Instructions, 09/2022, A5E41702836F AL
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P884
Series: S220
Power unit: Thermal model overheat
converter
Meaning: The temperature difference between the chip and the heatsink has exceeded the permissible limit (only applies to switching frequencies above 16 kHz). See also: r0037
Possible causes
Source: SINAMICS S220 Converter P2218