Siemens A05000 fault code meaning

Siemens / A05000

Series: G110M, G120C, G120D, G120X, G120XA, G130-G150, S120-S150, S220

Power unit: Inverter heatsink overheat

converter

Meaning: The inverter heatsink has reached the overheat alarm threshold. The overheat response is set via p0290. If the heatsink temperature continues to rise by the value set in p0292[0], the system triggers fault F30004.

Possible causes

Source: SINAMICS G110M P698; SINAMICS G120C P672; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P863; SINAMICS G120X Converter P1369; SINAMICS G120XA PN Converter P1280; SINAMICS G130_G150 P1582; SINAMICS S120_S150 P2694; SINAMICS S220 Converter P2216

Series: G115D

"Overtemperature heat sink AC inverter"

converter

Meaning:

Possible causes

Source: SINAMICS G115D P687

Series: G120-CU240B-E-2, G120-CU250S-2

Power unit: Inverter heatsink overheat

converter

Meaning: The inverter heatsink has reached the overheat alarm threshold. The overheat response is set via p0290. If the heatsink temperature continues to rise 5K, fault F30004 will occur.

Possible causes

Source: SINAMICS G120, Control Unit CU240B-2_CU240E-2 P729; SINAMICS G120, Control Unit CU250S-2 P1356

Series: S110

Power unit: Inverter heatsink overheat

servo drive

Meaning: The inverter heatsink has reached the overheat alarm threshold. The overheat response is set via p0290. If the heatsink temperature continues to rise 5K, fault F30004 will occur.

Possible causes

Source: SINAMICS S110 P1002

Series: S210

Power unit: Inverter heatsink overheat

servo drive

Meaning: The inverter heatsink has reached the overheat alarm threshold. The overheat response is set via p0290. If the heatsink temperature continues to rise by the value set in p0292[0], the system triggers fault F30004.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P884