Siemens A035 fault code meaning

Siemens / A035

Series: 6RA70

Drive stalled

DC drive

Meaning: (Valid in operating states – –, I, II) The monitoring function responds if the following conditions persist for longer than the time set in parameter P355: The positive or negative torque or armature current limit is reached; the armature current exceeds one percent of the rectifier rated DC armature current; the actual speed is below 0.4% of the maximum speed.

Possible causes

Source: 6ra70_c P441