Siemens A02062 fault code meaning
Siemens / A02062
Series: DCM-6RA80
Trace: Invalid trigger signal
DC drive
Meaning: No trigger signal has been specified. - The specified signal does not exist. - The specified signal is not a fixed-point signal. - The specified signal cannot be used as a trace trigger signal. See also: p4711 (Trace trigger signal).
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P996
Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G200, G210, G210X, G220, S220
Trace: Invalid trigger signal
converter
Meaning: No trigger signal has been specified. - The specified signal does not exist. - The specified signal is not a fixed-point signal. - The specified signal cannot be used as a trace trigger signal.
Possible causes
Source: SINAMICS G110M P694; SINAMICS G115D P750; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P725; SINAMICS G120, Control Unit CU250S-2 P1349; SINAMICS G120C P668; SINAMICS G200 Converter P694; SINAMICS G210 Converter P1087; SINAMICS G210X Converter P949; SINAMICS G220 Converter P1294; SINAMICS S220 Converter P2205
Series: G120D
Trace: Invalid trigger signal
converter
Meaning:
Possible causes
Source: SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P858
Series: G120X
Trace: Invalid trigger signal
converter
Meaning: No trigger signal has been specified. - The specified signal does not exist. - The specified signal is not a fixed-point signal. - The specified signal cannot be used as a trace trigger signal. See also: p4711 (Trace trigger signal).
Possible causes
Source: SINAMICS G120X Converter P1364
Series: G130-G150, S120-S150
Trace: Invalid trigger signal
converter
Meaning: No trigger signal has been specified. - The specified signal does not exist. - The specified signal is not a fixed-point signal. - The specified signal cannot be used as a trace trigger signal. See also: p4711 (Trace trigger signal)
Possible causes
Source: SINAMICS G130_G150 P1570;SINAMICS S120_S150 P2680
Series: S110
Trace: Invalid trigger signal
servo drive
Meaning: No trigger signal is specified. - The specified signal does not exist. - The specified signal is not a fixed-point signal. - The specified signal cannot be used as a trace trigger signal. See: p4711 (Trace trigger signal).
Possible causes
Source: SINAMICS S110 P998
Series: S200
Trace: Invalid trigger signal
servo drive
Meaning: No trigger signal has been specified. - The specified signal does not exist. - The specified signal is not a fixed-point signal. - The specified signal cannot be used as a trace trigger signal.
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P507