Siemens A02059 fault code meaning

Siemens / A02059

Series: DCM-6RA80

Trace: Invalid time slice cycle for recording channel 2 x 8

DC drive

Meaning: The selected time slice period cannot be used for more than 4 recording channels. See also: p4723 (trace time slice clock cycle)

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P995

Series: G110M, G115D, G120-CU240B-E-2, G120-CU250S-2, G120C, G120D, G200, G210, G220, S220

Trace: Invalid time slice cycle for recording channel 2 x 8

converter

Meaning: The selected time slice cycle cannot be used for more than 4 recording channels.

Possible causes

Source: SINAMICS G110M P693; SINAMICS G115D P750; SINAMICS G120, Control Unit CU240B-2_CU240E-2 P724; SINAMICS G120, Control Unit CU250S-2 P1349; SINAMICS G120C P668; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P858; SINAMICS G200 Basic Converter P568; SINAMICS G210 Converter P1086; SINAMICS G220 Converter P1293; SINAMICS S220 Converter P2205

Series: G120X

Trace: Invalid time slice cycle for recording channel 2 x 8

converter

Meaning: The selected time slice period cannot be used for more than 4 recording channels. See also: p4723 (trace time slice clock cycle). Alarms, faults and system messages 10.6 List of fault codes and alarm codes SINAMICS G120X Converter Operating Instructions, 06/2021, FW V1.04, A5E44751209F AF 1361

Possible causes

Source: SINAMICS G120X Converter P1363

Series: G130-G150, S120-S150

Trace: Invalid time slice cycle for recording channel 2 x 8

converter

Meaning: The selected time slice cycle cannot be used for more than 4 recording channels. See also: p4723 (Trace time slice clock cycle)

Possible causes

Source: SINAMICS G130_G150 P1569;SINAMICS S120_S150 P2680

Series: G210X

Trace: Invalid time slice cycle for recording channel 2 x 8

converter

Meaning:

Possible causes

Source: SINAMICS G210X Converter P948

Series: S110

Trace: Invalid time slice cycle for recording channel 2 x 8

servo drive

Meaning: The selected time slice cycle cannot be used for more than 4 recording channels. See: p4723 (Trace time slice clock cycle).

Possible causes

Source: SINAMICS S110 P998

Series: S200

Trace: Invalid time slice cycle for recording channel 2 x 8

servo drive

Meaning: The selected time slice cycle cannot be used for more than 4 recording channels.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P506