Siemens A02041 fault code meaning

Siemens / A02041

Series: DCM-6RA80

Function generator: Incorrect bandwidth value

DC drive

Meaning: The bandwidth setting is too large or too small relative to the function generator time slice. The bandwidth is determined by the time slice period as follows: Bandwidth_maximum = 1/(2 x time slice period). Bandwidth_minimum = Bandwidth_maximum / 100000. Example: Assumption: p4830 = 125 us --> Bandwidth_maximum = 1 / (2 x 125 us) = 4000 Hz --> Bandwidth_minimum = 4000 Hz / 100000 = 0.04 Hz.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P993

Series: G120-CU250S-2

Function generator: Incorrect bandwidth value

converter

Meaning: The bandwidth setting is too large or too small relative to the function generator time slice. The bandwidth is determined by the time slice period as follows: Maximum bandwidth = 1/(2 x time slice period). Minimum bandwidth = Maximum bandwidth / 100000. Example: Assuming p4830 = 125 microseconds --> Maximum bandwidth = 1 / (2 x 125 microseconds) = 4000 Hz --> Minimum bandwidth = 4000 Hz / 100000 = 0.04 Hz

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1347

Series: G130-G150, S120-S150

Function generator: Incorrect bandwidth value

converter

Meaning: The bandwidth setting is too large or too small relative to the function generator time slice. Depending on the time slice period, the bandwidth is determined as follows: Bandwidth_maximum = 1/(2 x time slice period) Bandwidth_minimum = Bandwidth_maximum / 100000 Example: Assumption: p4830 = 125 us --> Bandwidth_maximum = 1 / (2 x 125 us) = 4000 Hz --> Bandwidth_minimum = 4000 Hz / 100000 = 0.04 Hz

Possible causes

Source: SINAMICS G130_G150 P1567;SINAMICS S120_S150 P2677

Series: G200, G210, G210X, S220

Function generator: Incorrect bandwidth value

converter

Meaning: The bandwidth setting is too large or too small relative to the function generator time slice. Depending on the time slice period, the bandwidth is determined as follows: Bandwidth_maximum = 1/ (2 x time slice period) Bandwidth_minimum = Bandwidth_maximum / 100000 Example: Assumption: time slice period = 125 us --> Bandwidth_maximum = 1 / (2 x 125 us) = 4000 Hz --> Bandwidth_minimum = 4000 Hz / 100000 = 0.04 Hz

Possible causes

Source: SINAMICS G200 converter P692; SINAMICS G210 converter P1085; SINAMICS G210X converter P947; SINAMICS S220 converter P2203

Series: G220

Function generator: Incorrect bandwidth value

converter

Meaning:

Possible causes

Source: SINAMICS G220 Converter P1291

Series: S110

Function generator: Incorrect bandwidth value

servo drive

Meaning: The bandwidth setting is too large or too small relative to the function generator time slice. The bandwidth is determined by the time slice period as follows: Maximum bandwidth = 1/(2 x time slice period). Minimum bandwidth = Maximum bandwidth / 100000. Example: Assuming p4830 = 125 microseconds --> Maximum bandwidth = 1 / (2 x 125 microseconds) = 4000 Hz --> Minimum bandwidth = 4000 Hz / 100000 = 0.04 Hz

Possible causes

Source: SINAMICS S110 P996

Series: S200

Function generator: Incorrect bandwidth value

servo drive

Meaning: The bandwidth setting is too large or too small relative to the function generator time slice. Depending on the time slice period, the bandwidth is determined as follows: Bandwidth_maximum = 1/ (2 x time slice period) Bandwidth_minimum = Bandwidth_maximum / 100000 Example: Assumption: Time slice period = 125 us --> Bandwidth_maximum = 1 / (2 x 125 us) = 4000 Hz --> Bandwidth_minimum = 4000 Hz / 100000 = 0.04 Hz

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P505