Siemens A01945 fault code meaning

Siemens / A01945

Series: DCM-6RA80

PROFIBUS: Connection fault with the publisher

DC drive

Meaning: %1 bin Message class: Communication fault with the higher-level controller (9). Drive object: All objects. Component: None. Broadcast: LOCAL. Response: None. Acknowledgment: None. Cause: In PROFIBUS slave-to-slave communication, the connection to at least one publisher has a fault.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P985

Series: G110M, G120C, G120D

PROFIBUS: Connection fault with the publisher

converter

Meaning: In PROFIBUS slave-to-slave communication, a fault has occurred in the connection to at least one publisher.

Possible causes

Source: SINAMICS G110M P691; SINAMICS G120C P666; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P856

Series: G115D

PROFIBUS: Connection fault with the publisher

converter

Meaning:

Possible causes

Source: SINAMICS G115D P747

Series: G120-CU240B-E-2

PROFIBUS: Connection fault with the publisher

converter

Meaning: In PROFIBUS slave-to-slave communication, the connection to at least one publisher has failed. Warning value (r2124, binary): Bit 0 = 1: Connection fault with the publisher whose address is in r2077[0]. ... Bit 15 = 1: Connection fault with the publisher whose address is in r2077[15].

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P661

Series: G120-CU250S-2

PROFIBUS: Connection fault with the publisher

converter

Meaning: %1 bin Drive object: CU250S_V, CU250S_V_CAN, CU250S_V_DP, CU250S_V_PN. Reaction: None. Acknowledgment: None. Cause: In PROFIBUS slave-to-slave communication, the connection to at least one publisher has a fault.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1341

Series: G120X, G120XA

PROFIBUS: Connection fault with the publisher

converter

Meaning: In PROFIBUS slave-to-slave communication, the connection to at least one publisher has a fault.

Possible causes

Source: SINAMICS G120X Converter P1362; SINAMICS G120XA PN Converter P1277

Series: G130-G150, S120-S150

PROFIBUS: Connection fault with the publisher

converter

Meaning: %1 bin Message class: Communication fault with the higher-level controller (9) Drive object: All objects Component: None Broadcast: LOCAL Reaction: None Acknowledgment: None Cause: In PROFIBUS slave-to-slave communication, the connection to at least one publisher has failed.

Possible causes

Source: SINAMICS G130_G150 P1558; SINAMICS S120_S150 P2667

Series: S110

PROFIBUS: Connection fault with the publisher

servo drive

Meaning: %1 bin Drive object: All objects. Reaction: None. Acknowledgment: None. Cause: In PROFIBUS slave-to-slave communication, the connection to at least one publisher has failed.

Possible causes

Source: SINAMICS S110 P991