Siemens A01944 fault code meaning

Siemens / A01944

Series: G120-CU250S-2

PB/PN sign-of-life synchronization not achieved

converter

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous operation has been selected via the configuration telegram, but synchronization with the master sign-of-life (STW2.12 ... STW2.15) is not yet possible because the sign-of-life changes outside the configured time frame Tmapc.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P954

Series: G130-G150, S120-S150

PB/PN: Sign-of-life synchronization not achieved

converter

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous operation has been selected via the configuration telegram, but synchronization with the master sign-of-life (STW2.12 ... STW2.15) is not yet possible because the sign-of-life changes outside the configured time frame Tmapc.

Possible causes

Source: SINAMICS G130_G150 P1558; SINAMICS S120_S150 P2667

Series: G200

PN: Sign-of-life synchronization not achieved

converter

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization according to the controller sign of life (STW2.12 ... STW2.15) could not be performed because the sign of life changes at a different interval from the time grid set in Tmapc.

Possible causes

Source: SINAMICS G200 Basic converter P560

Series: G210

PN: Heartbeat signal synchronization not reached

converter

Meaning:

Possible causes

Source: SINAMICS G210 Converter P1077

Series: G210X, G220, S220

PN: Heartbeat signal synchronization not reached

converter

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization has been selected via the telegram setting. However, synchronization with the controller heartbeat signal (STW2.12 ... STW2.15) could not be performed because the heartbeat signal changes at a different interval from that configured in time grid Tmapc.

Possible causes

Source: SINAMICS G210X converter P940; SINAMICS G220 converter P1284; SINAMICS S220 converter P2194

Series: S110

PB/PN sign-of-life synchronization not achieved

servo drive

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization is selected via the configuration telegram, but synchronization with the master sign of life (STW2.12 ... STW2.15) cannot yet be performed because the sign of life changes outside the configured time frame Tmapc.

Possible causes

Source: SINAMICS S110 P991

Series: S200, S210

PN: Sign-of-life synchronization not achieved

servo drive

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization according to the controller sign of life (STW2.12 ... STW2.15) could not be performed because the sign of life changes at a different interval from the time grid set in Tmapc.

Possible causes

Source: SINAMICS S200 Compact_SIMOTICS S-1FL2 and S-1FL1 P475; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1312