Siemens A01940 fault code meaning

Siemens / A01940

Series: DCM-6RA80

PB/PN: Isochronous synchronization not achieved

DC drive

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization with the cycle specified by the master is still not possible. - Although isochronous mode has been selected in the bus configuration, the master does not send an isochronous global control telegram. - The master uses a different isochronous DP cycle from the cycle in the configuration telegram transmitted to the slave. - At least one drive object has pulse enable (not controlled via PROFIBUS-/PROFINET).

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P984

Series: G120-CU250S-2

PB/PN isochronous synchronization not achieved

converter

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous operation has been selected via the configuration telegram, but synchronization with the cycle specified by the master is still not possible. - Although isochronous operation has been selected in the bus configuration, the master does not send an isochronous global control telegram. - The master uses a different isochronous DP cycle from the cycle in the configuration telegram transmitted to the slave. - At least one drive object has pulse enable active (not controlled via PROFIBUS-/PROFINET).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1340

Series: G130-G150, S120-S150

PB/PN: Isochronous synchronization not achieved

converter

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization with the cycle specified by the master is still not possible. - Although isochronous mode has been selected in the bus configuration, the master is not sending isochronous global control telegrams. - The master uses a different isochronous DP cycle from the cycle in the configuration telegram sent to the slave. - Pulses are enabled for at least one drive object (not controlled via PROFIBUS/PROFINET).

Possible causes

Source: SINAMICS G130_G150 P1557; SINAMICS S120_S150 P2666

Series: G200, G210, G210X, G220, S220

PN: Isochronous synchronization not achieved

converter

Meaning: The bus is in the data exchange status (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization cannot be performed at the cycle specified by the controller. - Although isochronous run has been selected in the bus configuration, the controller is not sending isochronous telegrams. - The controller uses a different isochronous bus cycle from the cycle used to transmit the configuration telegram to the device.

Possible causes

Source: SINAMICS G200 Basic converter P559; SINAMICS G210 converter P1077; SINAMICS G210X converter P939; SINAMICS G220 converter P1283; SINAMICS S220 converter P2193

Series: S110

PB/PN isochronous synchronization not achieved

servo drive

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous operation has been selected via the configuration telegram, but synchronization with the cycle specified by the master is still not possible. - Although isochronous operation has been selected in the bus configuration, the master does not send an isochronous global control telegram. - The master uses a different isochronous DP cycle from the cycle in the configuration telegram transmitted to the slave. - At least one drive object has pulse enable active (not controlled via PROFIBUS-/PROFINET).

Possible causes

Source: SINAMICS S110 P990

Series: S200

PN: Isochronous synchronization not achieved

servo drive

Meaning: The bus is in the data exchange status (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization cannot be performed at the cycle specified by the controller. - Although isochronous run has been selected in the bus configuration, the controller is not sending isochronous telegrams. - The controller uses a different isochronous bus cycle from the cycle used to transmit the configuration telegram to the device.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P501

Series: S210

PN: Isochronous synchronization not achieved

servo drive

Meaning: The bus is in the data exchange state (Data Exchange), and isochronous synchronization has been selected via the configuration telegram, but synchronization with the cycle specified by the master is still not possible. - Although isochronous mode was selected in the bus configuration, the master does not send an isochronous global control telegram. - The master uses a different isochronous DP cycle from the cycle specified in the configuration telegram sent to the slave. - At least one drive object has pulse enable (not controlled via PROFINET). Faults and alarms 15.2 List of faults and alarms SINAMICS S210 servo drive system 492 Operating Instructions, 01/2019, A5E41702836F AC

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 P494