Siemens A01932 fault code meaning
Siemens / A01932
Series: G120-CU250S-2
"PB/PN clock cycle synchronization missing for DSC
converter
Meaning:
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1044
Series: G130-G150, S120-S150
PB/PN: Isochronous synchronization missing in DSC
converter
Meaning:
Possible causes
Source: SINAMICS G130_G150 P1556; SINAMICS S120_S150 P2665
Series: G200, G210X, G220
PN: Isochronous synchronization missing in DSC
converter
Meaning: DSC is selected, but isochronous synchronization or its heartbeat signal is missing. Note: DSC: Dynamic Servo Control (dynamic servo control). See also: r0922 (IF1 PROFIdrive PZD telegram).
Possible causes
Source: SINAMICS G200 converter P684; SINAMICS G210X converter P939; SINAMICS G220 converter P1283
Series: G210
PN: Isochronous synchronization missing in DSC
converter
Meaning:
Possible causes
Source: SINAMICS G210 Converter P1076
Series: S110
DSC: PB/PN isochronous synchronization missing
servo drive
Meaning: DSC is selected, but neither isochronous synchronization nor an isochronous sign of life is present.
Possible causes
Source: SINAMICS S110 P990
Series: S200
PN: Isochronous synchronization missing in DSC
servo drive
Meaning: DSC is selected, but isochronous synchronization or the isochronous synchronization sign of life is missing. Note: DSC: Dynamic Servo Control (Dynamic Servo Control) See also: r0922 (IF1 PROFIdrive PZD telegram)
Possible causes
Source: SINAMICS S200 Compact_SIMOTICS S-1FL2 and S-1FL1 P474
Series: S210
PN: Isochronous synchronization missing in DSC
servo drive
Meaning: DSC is selected, but isochronous synchronization or its sign-of-life signal is missing. Note: DSC: Dynamic Servo Control (Dynamic Servo Control). See also: r0922 (PROFIdrive PZD telegram selection).
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1311
Series: S220
PN: Isochronous synchronization missing in DSC
converter
Meaning: DSC is selected, but isochronous synchronization or its heartbeat signal is missing. Note: DSC: Dynamic Servo Control (Dynamic Servo Control) See also: r0922, c1190, c1191
Possible causes
Source: SINAMICS S220 converter P2193