Siemens A01788 fault code meaning

Siemens / A01788

Series: G110M, G120C, G120D, G130-G150, S120-S150

SI: Auto forced fault check waiting for cancellation by motion monitoring STO

converter

Meaning: The auto forced fault check has not yet been possible since start. Possible causes: - The STO function is selected via safe motion monitoring. - A safety message for triggering STO is present.

Possible causes

Source: SINAMICS G110M P689; SINAMICS G120C P664; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P854; SINAMICS G130_G150 P1547; SINAMICS S120_S150 P2654

Series: G120-CU250S-2

Auto test stop: Waiting for STO to be canceled via SMM

converter

Meaning: STO is triggered by selecting STO via the extended safety functions or by a safety message. The automatic test stop cannot yet be performed following startup. The test stop is performed automatically after STO is deselected.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P951

Series: S210

SI: Auto forced fault check waiting for cancellation by motion monitoring STO

servo drive

Meaning: The auto forced fault check has not yet been possible since start. Possible causes: - The STO function is selected via safe motion monitoring. - A safety message for triggering STO is present.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P877