Siemens A01697 fault code meaning
Siemens / A01697
Series: G115D, G120D, G130-G150
SI motion: Forced fault check for motion monitoring required
converter
Meaning: The time set in p9559 for the forced checking procedure for the motion monitoring functions has been exceeded. Selecting the forced checking procedure again clears the message and resets the monitoring time.
Possible causes
Source: SINAMICS G115D P739; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P844; SINAMICS G130_G150 P1523
Series: G120-CU240B-E-2
SI Motion: Motion monitoring test required
converter
Meaning: The forced fault check time for the motion monitoring function configured in p9559 has been exceeded. A new test is therefore required. When the forced fault check configured in p9705 is selected again, this message disappears and the monitoring time is reset. Note: This message does not initiate a stop response. The shutdown paths are not checked automatically during startup, so this warning is always present after startup. See: p9559 (SI Motion forced fault check timer (processor 1)), p9705 (SI Motion forced fault check signal source)
Possible causes
Source: SINAMICS G120 Control Unit CU240B_E-2 P653
Series: G120-CU250S-2
SI Motion: Motion monitoring test required
converter
Meaning: The time set in p9559 for the forced checking procedure of the motion monitoring function has been exceeded. A new test is therefore required. When the forced checking procedure set in p9705 is selected again, this message disappears and the monitoring time is reset.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P1326
Series: S110
SI Motion: Motion monitoring test required
servo drive
Meaning: The time set in p9559 for the forced checking procedure of the motion monitoring function has been exceeded. A new test is therefore required. When the forced checking procedure set in p9705 is selected again, this message disappears and the monitoring time is reset.
Possible causes
Source: SINAMICS S110 P971
Series: S120-S150
SI Motion: Motion monitoring test required
converter
Meaning:
Possible causes
Source: SINAMICS S120 Drive Function Manual P761
Series: S210
SI motion: Forced fault check for motion monitoring required
servo drive
Meaning: The time set in p9559 for the forced checking procedure for the motion monitoring functions has been exceeded. Selecting the forced checking procedure again clears the message and resets the monitoring time.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P865