Siemens A01631 fault code meaning

Siemens / A01631

Series: G120-CU250S-2

SI P1: Motor brake applied (holding)/SBC configuration is meaningless

converter

Meaning: An invalid combination of motor holding brake configuration and SBC was detected. The following configurations may trigger the message: - "No motor holding brake available" (p1215 = 0) and "SBC" enabled (p9602 = 1). - "Motor holding brake controlled by sequence control, connected via BICO" (p1215 = 3) and "SBC" enabled (p9602 = 1).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1318

Series: S210

SI P1: Motor brake applied (holding)/SBC configuration is meaningless

servo drive

Meaning: An implausible motor holding brake configuration and SBC were detected. The following configuration may trigger the message: - "No motor holding brake present" (p1215 = 0) and "SBC" enabled (p9602 = 1).

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P849