Siemens A01590 fault code meaning

Siemens / A01590

Series: DCM-6RA80

Drive: Motor maintenance interval expired

DC drive

Meaning: %1 bin Message class: General drive fault (19). Drive object: CU_DC, CU_DC_R, CU_DC_R_S, CU_DC_S, TM150, TM15DI_DO, TM31. Component: Motor. Broadcast: GLOBAL. Response: None. Acknowledgment: None. Cause: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P978

Series: G110M, G120C, G120D, G120X, G120XA

Drive: Motor maintenance interval expired

converter

Meaning:

Possible causes

Source: SINAMICS G110M P677; SINAMICS G120C P652; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P829; SINAMICS G120X Converter P1360; SINAMICS G120XA PN Converter P1275

Series: G115D

Drive: Motor maintenance interval expired

converter

Meaning: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS G115D P725

Series: G120-CU230P-2, G120P-Cabinet

Motor maintenance interval has elapsed

converter

Meaning:

Possible causes

Source: Converter SINAMICS G120, equipped with control unit CU230P-2 P491; SINAMICS G120P Cabinet P509

Series: G120-CU240B-E-2

Drive: Motor maintenance interval expired

converter

Meaning: The maintenance interval set for this motor has been reached. Warning value (r2124, decimal): Motor data set code. See: p0650 (Current motor operating hours), p0651 (Motor maintenance interval (hours)).

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P646

Series: G120-CU250S-2

Drive: Motor maintenance interval expired

converter

Meaning: %1 bin Drive object: All objects. Reaction: None. Acknowledgment: None. Cause: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1314

Series: G130-G150

Drive: Motor maintenance interval expired

converter

Meaning: %1 bin Message class: General drive fault (19) Drive object: All objects Component: Motor Broadcast: GLOBAL Reaction: None Acknowledgment: None Cause: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS G130_G150 P1484

Series: G200

Drive: Motor maintenance interval expired

converter

Meaning: %1 bin Component: Motor. Reaction: None. Acknowledgment: None. Cause: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS G200 Basic converter P548

Series: S110

Drive: Motor maintenance interval expired

servo drive

Meaning: %1 bin Drive object: SERVO_S110-CAN, SERVO_S110-DP, SERVO_S110-PN. Reaction: None. Acknowledgment: None. Cause: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS S110 P950

Series: S210

Drive: Motor maintenance interval expired

servo drive

Meaning: The maintenance interval set for this motor has been reached.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P844