Siemens A01514 fault code meaning
Siemens / A01514
Series: DCM-6RA80
BICO: Error writing during reconnection
DC drive
Meaning: Parameters cannot be written during reconnection (e.g. during start or download, although this may also occur during normal operation). Example: When data is written to the second index at the BICO input in double-word format (DWORD), the memory areas overlap (e.g. p8861). The parameters are then restored to their factory settings.
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P978
Series: G110M, G115D, G120-CU250S-2, G120C, G120D, S120-S150
BICO: Error writing during reconnection
converter
Meaning: Parameters cannot be written during reconnection (for example, at start or during a download, although this may also occur during normal operation). Example: When data is written to the second subindex in double-word format (DWORD) at input BICO, the memory ranges overlap (for example, p8861). The parameters are then reset to factory settings.
Possible causes
Source: SINAMICS G110M P677; SINAMICS G115D P725; SINAMICS G120, Control Unit CU250S-2 P1314; SINAMICS G120C P652; SINAMICS G120D Control Unit CU240D- 2_CU250D- 2 P829; SINAMICS S120_S150 P2560
Series: G120-CU240B-E-2
BICO: Error writing during reconnection
converter
Meaning: Parameters cannot be written during reconnection (for example, at start or during download, although this can also occur during normal operation). Example: When writing data to the DWord-BICO input at the second index, memory areas overlap, for example: p8861. The parameters are then restored to their factory settings. Warning value (r2124, decimal): Parameter number of the BICO input (signal sink).
Possible causes
Source: SINAMICS G120 control unit CU240B_E-2 P645
Series: G120X, G120XA
BICO: Error writing during reconnection
converter
Meaning: Parameters cannot be written during reconnection (for example, during start or download, although this may also occur during normal operation). Example: Writing data to the second subindex in double-word format (DWORD) at input BICO causes memory areas to overlap (for example, p8861). The parameters are then reset to factory settings.
Possible causes
Source: SINAMICS G120X Converter P1360; SINAMICS G120XA PN Converter P1275
Series: G130-G150
BICO: Error when writing during a reconnect
converter
Meaning:
Possible causes
Source: G150 P823
Series: G200, G210, G210X, G220, S220
Error writing during reconnection
converter
Meaning: Parameters cannot be written during reconnection (for example, during start or download, or during normal operation). Example: When data is written to the second index of a signal sink in double-word format (DWORD), memory areas overlap. The parameters are then restored to factory settings.
Possible causes
Source: SINAMICS G200 converter P665; SINAMICS G210 converter P1044; SINAMICS G210X converter P911; SINAMICS G220 converter P1244; SINAMICS S220 converter P2146
Series: S110
BICO: Error writing during reconnection
servo drive
Meaning: Parameters cannot be written during reconnection (for example, at start or during download, but this can also occur during normal operation). Example: When writing data to the DWord-BICO input at the second index, memory areas overlap, for example: p8861. The parameters are then restored to the factory settings.
Possible causes
Source: SINAMICS S110 P950