Siemens A01324 fault code meaning

Siemens / A01324

Series: DCM-6RA80

Topology: Error creating a dummy drive object number

DC drive

Meaning: In p0978, dummy drive object numbers (255) are permitted only in the first sublist.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P954

Series: G120-CU250S-2, G130-G150, S120-S150

Topology: Error creating a dummy drive object number

converter

Meaning: In p0978, the dummy drive object number (255) is permitted only in the first sublist.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1296; SINAMICS G130_G150 P1459; SINAMICS S120_S150 P2536

Series: S110

Topology: Error creating a dummy drive object number

servo drive

Meaning: In p0978, the dummy drive object number (255) is permitted only in the first sublist.

Possible causes

Source: SINAMICS S110 P939

Series: S220

Topology: Error creating virtual drive object number

converter

Meaning: In p0978, the virtual drive object number (255) is permitted only in the first sublist.

Possible causes

Source: SINAMICS S220 Converter P2086