Siemens A01318 fault code meaning

Siemens / A01318

Series: DCM-6RA80

BICO: An open connection exists

DC drive

Meaning: This alarm is output in the following cases: - An invalid drive object or a drive object that is not ready for operation becomes valid or ready for operation again. - The list of BI/CI parameters is not empty (r9498[0...29], r9499[0...29]). - The BICO connections stored in the BI/CI parameter list have actually been changed (r9498[0...29], r9499[0...29]).

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P952

Series: G120-CU250S-2, G130-G150, S120-S150

BICO: An open connection exists

converter

Meaning: This alarm is output under the following conditions: - An invalid drive object or a drive object that is not ready to run becomes valid or ready to run again. - The list for parameter BI/CI is not empty (r9498[0...29], r9499[0...29]). - The BICO connections stored in the parameter list BI/CI have actually been changed (r9498[0...29], r9499[0...29]).

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1294; SINAMICS G130_G150 P1457; SINAMICS S120_S150 P2534

Series: S110

BICO: An open connection exists

servo drive

Meaning: This alarm is output under the following conditions: - An invalid drive object or a drive object that is not ready to run becomes valid or ready to run again. - The list for parameter BI/CI is not empty (r9498[0...29], r9499[0...29]). - The BICO connections stored in the parameter list BI/CI have actually been changed (r9498[0...29], r9499[0...29]).

Possible causes

Source: SINAMICS S110 P938