Siemens A01049 fault code meaning

Siemens / A01049

Series: DCM-6RA80

CU: Cannot write to file

DC drive

Meaning: The write-protected file (PSxxxxxx.acx) cannot be overwritten. The write task was interrupted.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P935

Series: G110M, G115D, G120-CU250S-2, G120C, G120D

Cannot write to file

converter

Meaning: Cannot overwrite the write-protected file (PSxxxxxx.acx). The write task was interrupted.

Possible causes

Source: SINAMICS G110M P670; SINAMICS G115D P718; SINAMICS G120, control unit CU250S-2 P1284; SINAMICS G120C P645; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P822

Series: G120-CU240B-E-2

Cannot write to file

converter

Meaning: The write-protected file (PSxxxxxx.acx) cannot be overwritten. The write task was interrupted. Warning value (r2124, decimal): Drive object number.

Possible causes

Source: SINAMICS G120 control unit CU240B_E-2 P642

Series: G120X, G120XA

Cannot write to file

converter

Meaning: The write-protected file (PSxxxxxx.acx) cannot be overwritten. The write task was interrupted.

Possible causes

Source: SINAMICS G120X Converter P1353; SINAMICS G120XA PN Converter P1268

Series: G130-G150, S120-S150

CU: Cannot write to file

converter

Meaning: Cannot overwrite the write-protected file (PSxxxxxx.acx). The write task was interrupted.

Possible causes

Source: SINAMICS G130_G150 P1439; SINAMICS S120_S150 P2515

Series: G200, G210, G210X, G220

Cannot write to file

converter

Meaning: Cannot write to the write-protected parameter backup file. The write task was interrupted.

Possible causes

Source: SINAMICS G200 converter P612; SINAMICS G210 converter P984; SINAMICS G210X converter P852; SINAMICS G220 converter P1186

Series: S110

CU: Cannot write to file

servo drive

Meaning: Cannot overwrite the write-protected file (PSxxxxxx.acx). The write task was interrupted.

Possible causes

Source: SINAMICS S110 P930

Series: S200

CU: Cannot write to file

servo drive

Meaning: Cannot write to the write-protected parameter backup file. The write task was interrupted.

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P455

Series: S210

CU: Cannot write to file

servo drive

Meaning: The write-protected file (PSxxxxxx.acx) cannot be overwritten. The write task was interrupted.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P838

Series: S220

CU: Cannot write to file

converter

Meaning: Cannot write to the write-protected parameter backup file. The write task was interrupted.

Possible causes

Source: SINAMICS S220 Converter P2064