Siemens A01045 fault code meaning

Siemens / A01045

Series: DCM-6RA80

CU: Invalid design data

DC drive

Meaning: An error was detected when using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX, or CCxxxyyy.ACX saved in non-volatile memory. As a result, some of the saved parameter values may not be received. See also r9406 to r9408.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P935

Series: G110M, G115D, G120-CU240B-E-2, G120C, G120D

Invalid design data

converter

Meaning: An error was detected when using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX, or CCxxxyyy.ACX saved in non-volatile memory. As a result, some of the saved parameter values may not be received. See also r9406 to r9408.

Possible causes

Source: SINAMICS G110M P670; SINAMICS G115D P718; SINAMICS G120, control unit CU240B-2_CU240E-2 P695; SINAMICS G120C P645; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P822

Series: G120-CU250S-2

Invalid design data

converter

Meaning: An error was detected while using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX, or CCxxxyyy.ACX saved in nonvolatile memory. As a result, some of the saved parameter values may not be received. See also r9406 to r9408.

Possible causes

Source: SINAMICS G120, Control Unit CU250S-2 P1284

Series: G120X, G120XA

Invalid design data

converter

Meaning: An error was detected while using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX, or CCxxxyyy.ACX saved in non-volatile memory. As a result, some of the saved parameter values cannot be received. See also r9406 to r9408.

Possible causes

Source: SINAMICS G120X Converter P1353; SINAMICS G120XA PN Converter P1268

Series: G130-G150, S120-S150

CU: Invalid design data

converter

Meaning: An error was found when using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX or CCxxxyyy.ACX saved in nonvolatile memory. As a result, some of the saved parameter values cannot be accepted. See also r9406 to r9408.

Possible causes

Source: SINAMICS G130_G150 P1439; SINAMICS S120_S150 P2515

Series: S110

CU: Invalid design data

servo drive

Meaning: An error was detected when using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX, or CCxxxyyy.ACX saved in nonvolatile memory.

Possible causes

Source: SINAMICS S110 P930

Series: S210

CU: Invalid design data

servo drive

Meaning: An error was detected when using parameter file PSxxxyyy.ACX, PTxxxyyy.ACX, CAxxxyyy.ACX or CCxxxyyy.ACX saved in nonvolatile memory. As a result, some parameter values saved in the file may not be received.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P838