Siemens A01035 fault code meaning
Siemens / A01035
Series: DCM-6RA80
ACX: Parameter backup file damaged
DC drive
Meaning:
Possible causes
Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P929
Series: G110M, G115D, G120-CU250S-2, G120C, G120D, G130-G150, S120-S150
ACX: Parameter backup file damaged
converter
Meaning: No complete data set was found in the parameter backup file when the control unit started. The previous parameter settings were not saved completely. The backup may have been interrupted by system shutdown or removal of the memory card.
Possible causes
Source: SINAMICS G110M P667; SINAMICS G115D P714; SINAMICS G120, control unit CU250S-2 P1277; SINAMICS G120C P642; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P819; SINAMICS G130_G150 P1433; SINAMICS S120_S150 P2508
Series: G120-CU240B-E-2
ACX: Start from parameter backup file
converter
Meaning: No complete data set was found in the parameter backup file at control unit start. The previous parameter settings were not saved completely. A backup data set or parameter backup file was loaded instead. Warning value (r2124, hexadecimal): For internal Siemens fault diagnostics only.
Possible causes
Source: SINAMICS G120 Control Unit CU240B_E-2 P639
Series: G120X, G120XA
ACX: Parameter backup file damaged
converter
Meaning:
Possible causes
Source: SINAMICS G120X converter P1349; SINAMICS G120XA PN converter P1264
Series: G200, G210, G210X
Parameter backup file damaged
converter
Meaning:
Possible causes
Source: SINAMICS G200 Basic converter P481; SINAMICS G210 converter P978; SINAMICS G210X converter P846
Series: G220
Parameter backup file damaged
converter
Meaning: At converter start, no complete data set was found in the parameter backup file. The previous parameter settings were not saved completely. The backup may have been interrupted by a power failure or removal of the memory card.
Possible causes
Source: SINAMICS G220 converter P1181
Series: S110
ACX: Start from parameter backup file
servo drive
Meaning: At control unit start, no complete data set was found in the parameter backup file. The previous parameter settings were not saved completely. A backup data set or parameter backup file was loaded instead.
Possible causes
Source: SINAMICS S110 P925
Series: S200
Parameter backup file damaged
servo drive
Meaning:
Possible causes
Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P449
Series: S210
Parameter backup file damaged
servo drive
Meaning: At converter start, a complete data set could not be found in the parameter backup file. The previous parameter settings were not saved completely. The backup may have been interrupted by system shutdown or removal of the memory card.
Possible causes
Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1259