Siemens A01035 fault code meaning

Siemens / A01035

Series: DCM-6RA80

ACX: Parameter backup file damaged

DC drive

Meaning:

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P929

Series: G110M, G115D, G120-CU250S-2, G120C, G120D, G130-G150, S120-S150

ACX: Parameter backup file damaged

converter

Meaning: No complete data set was found in the parameter backup file when the control unit started. The previous parameter settings were not saved completely. The backup may have been interrupted by system shutdown or removal of the memory card.

Possible causes

Source: SINAMICS G110M P667; SINAMICS G115D P714; SINAMICS G120, control unit CU250S-2 P1277; SINAMICS G120C P642; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P819; SINAMICS G130_G150 P1433; SINAMICS S120_S150 P2508

Series: G120-CU240B-E-2

ACX: Start from parameter backup file

converter

Meaning: No complete data set was found in the parameter backup file at control unit start. The previous parameter settings were not saved completely. A backup data set or parameter backup file was loaded instead. Warning value (r2124, hexadecimal): For internal Siemens fault diagnostics only.

Possible causes

Source: SINAMICS G120 Control Unit CU240B_E-2 P639

Series: G120X, G120XA

ACX: Parameter backup file damaged

converter

Meaning:

Possible causes

Source: SINAMICS G120X converter P1349; SINAMICS G120XA PN converter P1264

Series: G200, G210, G210X

Parameter backup file damaged

converter

Meaning:

Possible causes

Source: SINAMICS G200 Basic converter P481; SINAMICS G210 converter P978; SINAMICS G210X converter P846

Series: G220

Parameter backup file damaged

converter

Meaning: At converter start, no complete data set was found in the parameter backup file. The previous parameter settings were not saved completely. The backup may have been interrupted by a power failure or removal of the memory card.

Possible causes

Source: SINAMICS G220 converter P1181

Series: S110

ACX: Start from parameter backup file

servo drive

Meaning: At control unit start, no complete data set was found in the parameter backup file. The previous parameter settings were not saved completely. A backup data set or parameter backup file was loaded instead.

Possible causes

Source: SINAMICS S110 P925

Series: S200

Parameter backup file damaged

servo drive

Meaning:

Possible causes

Source: SINAMICS S200 PROFINET_SIMOTICS S-1FL2 P449

Series: S210

Parameter backup file damaged

servo drive

Meaning: At converter start, a complete data set could not be found in the parameter backup file. The previous parameter settings were not saved completely. The backup may have been interrupted by system shutdown or removal of the memory card.

Possible causes

Source: SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1259