Siemens A01032 fault code meaning

Siemens / A01032

Series: DCM-6RA80

ACX: All parameters must be stored

DC drive

Meaning: The parameters of a drive object have been stored (p0971 = 1) before all parameters of the drive system have been backed up. The stored parameters for this object will not be loaded at the next start. A complete parameter backup must be performed to ensure a successful start.

Possible causes

Source: SINAMICS DCM, Parameter Manual, firmware version 1.5 SP2 (based on 5.1 SP2) P929

Series: G130-G150, S120-S150

ACX: All parameters must be stored

converter

Meaning: The parameters of a drive object have been stored (p0971 = 1) before all parameters of the drive system have been backed up. The stored parameters for this object will not be loaded at the next start. A complete parameter backup must be performed to ensure a successful start.

Possible causes

Source: SINAMICS G130_G150 P1432; SINAMICS S120_S150 P2507

Series: G200, G210, G210X, G220

All parameters need to be saved

converter

Meaning: The data backup is incomplete. Some saved parameters will not be loaded at the next start. A complete parameter backup must be performed for a successful start.

Possible causes

Source: SINAMICS G200 converter P605; SINAMICS G210 converter P977; SINAMICS G210X converter P845; SINAMICS G220 converter P1179

Series: S200, S210

All parameters need to be saved

servo drive

Meaning: The data backup is incomplete. Some saved parameters will not be loaded at the next start. A complete parameter backup must be performed for a successful start.

Possible causes

Source: SINAMICS S200 Compact_SIMOTICS S-1FL2 and S-1FL1 P439; SINAMICS S210_SIMOTICS S-1FK2 and S-1FT2 P1258

Series: S220

All parameters need to be saved

converter

Meaning: The parameters of a drive object were saved in nonvolatile memory before all drive system parameters had been backed up. The stored parameters for this object will not be loaded at the next start. A complete parameter backup must be performed to ensure a successful start.

Possible causes

Source: SINAMICS S220 Converter P2056