Siemens A01017 fault code meaning
Siemens / A01017
Series: DCM-6RA80
Component list has been changed
DC drive
Meaning:
Possible causes
Source: SINAMICS DCM, Parameter Manual, Firmware Version 1.5 SP2 (based on 5.1 SP2) P926
Series: G110M, G115D, G120C, G120D, G130-G150
Component list has been changed
converter
Meaning:
Possible causes
Source: SINAMICS G110M P664; SINAMICS G115D P711; SINAMICS G120C P639; SINAMICS G120D control unit CU240D- 2_CU250D- 2 P816; SINAMICS G130_G150 P1430
Series: G120-CU240B-E-2
Component list has been changed
converter
Meaning: The factory settings of files in memory card directory /SIEMENS/SINAMICS/DATA or /ADDON/SINAMICS/DATA have been changed. Changes to this directory are not permitted. Warning value (r2124, decimal): zyx decimal: x = problem, y = directory, x = file name. x = 1: File does not exist. x = 2: File firmware version and software version mismatch. x = 3: File checksum mismatch. y = 0: Directory /SIEMENS/SINAMICS/DATA/ y = 1: Directory /ADDON/SINAMICS/DATA/ z = 0: File MOTARM.ACX z = 1: File MOTSRM.ACX z = 2: File MOTSLM.ACX z = 3: File ENCDATA.ACX z = 4: File FILTDATA.ACX z = 5: File BRKDATA.ACX z = 6: File DAT_BEAR.ACX z =
Possible causes
Source: SINAMICS G120 Control Unit CU240B_E-2 P637
Series: G120-CU250S-2, G120X, G120XA, S120-S150
Component list has been changed
converter
Meaning: The factory settings of files in the storage card directory /SIEMENS/SINAMICS/DATA or /ADDON/SINAMICS/DATA have been changed. Changes to this directory are not permitted.
Possible causes
Source: SINAMICS G120, Control Unit CU250S-2 P898; SINAMICS G120X converter P1347; SINAMICS G120XA PN converter P1262; SINAMICS S120_S150 P2506
Series: S110
Component list has been changed
servo drive
Meaning: The factory settings of files in the storage card directory /SIEMENS/SINAMICS/DATA or /ADDON/SINAMICS/DATA have been changed. Changes to this directory are not permitted.
Possible causes
Source: SINAMICS S110 P923