Inovance F66 fault code meaning
Inovance / F66
Series: HD5X
Unit overvoltage fault
AC drive
Meaning: Unit DC bus voltage exceeds the hardware overvoltage threshold
Possible causes
- 1.Mains voltage high
- 2. F2-12 (braking torque output upper limit) setting too high
- 3.Load inertia high and deceleration time (F0-18) setting too low
- 4.Overvoltage suppression function not enabled
- 5.Unit control board error
- 6.Output current oscillation
- 7.Input transformer fault
Source: HD5X Series High-Voltage AC Drive User Manual P121
Series: HD90P, HD90T, HD9X, HD9XS
Unit overvoltage fault
AC drive
Meaning:
Possible causes
Source: HD90P Series High-Voltage Variable-Frequency Power Supply User Manual P116; HD90T Series High-Voltage AC Drive User Manual P154; HD9X High-Voltage AC Drive User Manual P170; HD9XS Series High-Voltage AC Drive User Manual (Neutral) P188