Inovance Err45 fault code meaning
Inovance / Err45
Series: CP320, MD480
Motor overtemperature fault
AC drive
Meaning:
Possible causes
Source: CP320 Series Air Compressor AC Drive User Manual P50; MD480 Series Engineered Single-Drive AC Drive User Manual P89
Series: MD290, MD480P, MD500, MD500E
Motor temperature fault
AC drive
Meaning:
Possible causes
Source: MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD480P Series AC Drive User Manual P95; MD500 Series General-Purpose AC Drive Commissioning Manual P123; MD500E Series General-Purpose AC Drive User Manual P235
Series: MD380E
Motor overtemperature fault
AC drive
Meaning: Loose temperature sensor wiring; motor temperature too high
Possible causes
Source: MD380E Series AC Drive User Manual, Fault Diagnosis P250
Series: NICE1000, NICE3000dt
Upper and lower deceleration switches open
elevator controller
Meaning: Upper and lower stage 1 deceleration switches are both open at stop; forced deceleration is activated, and E045 is also displayed after elevator deceleration, but resets automatically after 2 seconds
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P81; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P122
Series: NICE7000
Forced deceleration switch error
elevator controller
Meaning: Upper forced deceleration switch 1 error; upper forced deceleration switch 1 stuck; upper forced deceleration switch 2 error; upper forced deceleration switch 2 stuck; upper forced deceleration switch 3 error; upper forced deceleration switch 3 stuck; lower forced deceleration switch 1 error; lower forced deceleration switch 1 stuck; lower forced deceleration switch 2 error; lower forced deceleration switch 2 stuck; lower forced deceleration switch 3 error; lower forced deceleration switch 3 stuck; during hoistway auto-tuning, the position of the lower first-stage forced deceleration switch is less than S=V×V/2a+V×0.3+0.1; during hoistway auto-tuning, the position of the lower first-stage forced deceleration switch is less than S=V×V/2a+V×0.3+0.1
Possible causes