Inovance Err42 fault code meaning
Inovance / Err42
Series: CL100, MD290, MD480, MD500, MD500E
Excessive speed deviation fault
AC drive
Meaning:
Possible causes
Source: CL100 Series Integrated Wire Drawing Machine User Manual P36; MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD480 Series Industrial Single-Drive AC Drive User Manual P89; MD500 Series General-Purpose AC Drive Commissioning Manual P123; MD500E Series General-Purpose AC Drive User Manual P235
Series: CP320
Fault
AC drive
Meaning:
Possible causes
Source: CP320 Series Air Compressor AC Drive User Manual P50
Series: MD200
Excessive speed deviation fault
AC drive
Meaning: The AC drive reports an excessive speed deviation fault when it detects that the deviation between the actual motor speed and the frequency setting exceeds F9-69 (excessive speed deviation detection value) for longer than F9-70 (excessive speed deviation detection time).
Possible causes
- 1: Incorrect encoder parameter settings
- 2: Auto-tuning has not been performed
- 3: Excessive speed deviation detection parameter F9-
- 69: Inappropriate F9-70 setting
Source: MD200 Series Basic AC Drive User Manual P40
Series: MD310
Excessive speed deviation fault
AC drive
Meaning: For excessive speed deviation protection, if the AC drive detects a deviation between the actual motor speed and the set frequency that exceeds F9-69 × maximum frequency F0-10 (Excessive speed deviation detection value) and persists longer than F9-70 (Excessive speed deviation detection time), the AC drive reports an excessive speed deviation fault (Err42) and responds according to F9-52 (Fault protection action mode). When F9-70 (Excessive speed deviation detection time) is set to 0.0s, excessive speed deviation fault detection is disabled. The excessive speed deviation protection function is valid only when the AC drive operates in SVC mode (F0-01=1).
Possible causes
- Auto-tuning has not been performed
- Inappropriate settings for excessive speed deviation detection parameters F9-69 and F9-70
Source: MD310 Series General-Purpose AC Drive User Manual P236
Series: MD380E
Excessive speed deviation fault
AC drive
Meaning: Incorrect encoder parameter settings; parameter tuning not performed; excessive speed deviation detection parameters F9-; F9-70 set inappropriately
Possible causes
Source: MD380E Series AC Drive User Manual, Fault Diagnosis P250
Series: NICE1000, NICE3000dt
Door interlock open during operation
elevator controller
Meaning: Door lock circuit feedback indicates an open circuit during elevator operation
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P81; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P122
Series: NICE7000
Door interlock open during operation
elevator controller
Meaning: 101: Door lock feedback is invalid during elevator operation
Possible causes
Source: NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P60