Inovance Err40 fault code meaning
Inovance / Err40
Series: CP320, MD290, MD480, MD480P, MD500
Cycle-by-cycle current limiting fault
AC drive
Meaning:
Possible causes
Source: CP320 Series AC Drive for Air Compressors User Manual P50; MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD480 Series Engineered Single AC Drive User Manual P88; MD480P Series AC Drive User Manual P94; MD500 Series General-Purpose AC Drive Commissioning Manual P123
Series: MD200, MD310
Cycle-by-cycle current limiting fault
AC drive
Meaning: The cycle-by-cycle current limiting fault applies only in asynchronous motor V/f control mode: this fault is reported if cycle-by-cycle current limiting continues for 500ms after the current exceeds the cycle-by-cycle current limit threshold.
Possible causes
- 1, Check whether the load is too large or the motor has a locked rotor
- 2, AC drive undersized
Source: MD200 Series Basic AC Drive User Manual P40; MD310 Series General-Purpose AC Drive User Manual P235
Series: MD210, MD380E
Cycle-by-cycle current limiting fault
AC drive
Meaning: Check whether the load is too large or the motor has a locked rotor; the selected AC drive is undersized
Possible causes
Source: MD210 Series AC Drive User Manual, Fault Diagnosis P161; MD380E Series AC Drive User Manual, Fault Diagnosis P250
Series: MD280
Fast current limiting timeout fault
AC drive
Meaning:
Possible causes
Source: MD280 Series AC Drive User Manual Fault Record Parameters P71
Series: NICE1000, NICE3000dt
Elevator run timeout
elevator controller
Meaning: Elevator run time setting reached
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P81; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P122
Series: NICE7000
Elevator run timeout
elevator controller
Meaning: Elevator run timeout
Possible causes
Source: NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P60