Inovance Err33 fault code meaning
Inovance / Err33
Series: CAN600
Overspeed
AC drive
Meaning: Speed feedback exceeds F5-11~F5-15.
Possible causes
Source: CAN600 Series AC Drive User Manual Fault Diagnosis P89
Series: CS280
Run command fault
AC drive
Meaning: â—†Forward and reverse external run command inputs are valid simultaneously
Possible causes
Source: CS280 Series Construction Hoist AC Drive User Manual, Fault Diagnosis P109
Series: MD310
DSP driver board CAN communication fault
AC drive
Meaning: The driver board cannot receive CAN data from the control board
Possible causes
- Driver board CAN communication receive error
Source: MD310 Series General-Purpose AC Drive User Manual P235
Series: NICE1000
Elevator speed error
elevator controller
Meaning: Actual elevator speed exceeds 1.15 times the maximum elevator speed; speed during low-speed operation exceeds 1.2 times the setting; inspection switch activated during elevator auto operation
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P80
Series: NICE2000ft
Brake applied (holding) fault
elevator controller
Meaning: Brake release fault
Possible causes
Source: NICE2000(ft) Door Controller User Manual Fault Diagnosis P69
Series: NICE3000dt
Elevator speed error
elevator controller
Meaning: Actual elevator speed exceeds 1.15 times the maximum elevator operating speed; speed during low-speed operation exceeds 1.2 times the setting; inspection switch activated during auto elevator operation
Possible causes
Source: NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P121
Series: NICE7000
Elevator speed error
elevator controller
Meaning: 1: Overspeed during inspection operation or hoistway auto-tuning; 2: The run speed exceeds 1.15 times the maximum speed (F0-03); 3: The speed during gravity-driven operation or emergency operation exceeds 1/2 of the rated speed
Possible causes
Source: NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P59