Inovance Err19 fault code meaning
Inovance / Err19
Series: CAN600
Motor tuning fault
AC drive
Meaning: Incorrect motor parameter settings; parameter tuning timeout
Possible causes
Source: CAN600 Series AC Drive User Manual Fault Diagnosis P89
Series: CL100, MD280, MD300, MD320, MD320N, MD480P
Motor tuning fault
AC drive
Meaning:
Possible causes
Source: CL100 Series Integrated Wire Drawing Machine User Manual P36; MD280 Series AC Drive User Manual, Fault Record Parameters P71; MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77; MD480P Series AC Drive User Manual P94
Series: CP320
Fault
AC drive
Meaning:
Possible causes
Source: CP320 Series AC Drive for Air Compressors User Manual P49
Series: CS280
Motor tuning fault
AC drive
Meaning: â—†Incorrect motor parameter settings â—†Parameter tuning timeout
Possible causes
Source: CS280 Series Construction Hoist AC Drive User Manual, Fault Diagnosis P109
Series: MD200, MD310
Motor auto-tuning fault
AC drive
Meaning: This fault is reported if the current is too small during stator resistance auto-tuning.
Possible causes
- 1. Motor parameters are not set according to the nameplate.
- 2. Auto-tuning timeout.
Source: MD200 Series Basic AC Drive User Manual P38; MD310 Series General-purpose AC Drive User Manual P233
Series: MD210
Motor tuning fault
AC drive
Meaning: Motor parameters are not set according to the nameplate; auto-tuning timed out
Possible causes
Source: MD210 Series AC Drive User Manual, Fault Diagnosis P161
Series: MD290, MD480, MD500, MD500E
Motor auto-tuning fault
AC drive
Meaning:
Possible causes
Source: MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD480 Series Engineered Single AC Drive User Manual P88; MD500 Series General-Purpose AC Drive Commissioning Manual P122; MD500E Series General-Purpose AC Drive User Manual P235
Series: MD380E
Motor tuning fault under load
AC drive
Meaning: Torque upper limit F2-10 set too low; incorrect encoder line count, rated frequency, or rated speed setting; encoder PG card improperly connected or damaged; incorrect encoder type setting; load too heavy or incorrect F1-30 setting
Possible causes
Source: MD380E Series AC Drive User Manual, Fault Diagnosis P249
Series: NICE1000
Motor tuning fault
elevator controller
Meaning: Incorrect motor parameter settings; parameter tuning timeout; synchronous motor rotary encoder error
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P79
Series: NICE2000ft
Motor tuning fault
elevator controller
Meaning: Incorrect motor parameter settings; parameter tuning timeout
Possible causes
Source: NICE2000(ft) Door Controller User Manual Fault Diagnosis P69
Series: NICE3000dt
Motor tuning fault
elevator controller
Meaning: Motor cannot operate normally; parameter tuning timeout; synchronous motor rotary encoder error
Possible causes
Source: NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P120
Series: NICE7000
Motor tuning fault
elevator controller
Meaning: 102: Motor tuning takes too long, and the system stops
Possible causes