Inovance Err16 fault code meaning

Inovance / Err16

Series: CL100, CP320, MD021, MD320, MD320N

Communication fault

AC drive

Meaning:

Possible causes

Source: CL100 Series Integrated Wire Drawing Machine User Manual P35; CP320 Series Air Compressor AC Drive User Manual P49; MD021 Series AC Drive User Manual, Fault Record Parameters P26; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77

Series: CS280

Communication fault

AC drive

Meaning: ◆Check whether the RS485 communication wiring is correct ◆Check whether the parameter settings in group FD are correct

Possible causes

Source: CS280 Series Construction Hoist AC Drive User Manual, Fault Diagnosis P109

Series: MD200, MD310

Communication fault

AC drive

Meaning: 1. If the interval between consecutive communications exceeds FD-04 (Modbus communication interruption detection time) or FD-08 (extended communication interruption detection time), the system reports a communication fault. 2. If an error occurs in the connection to the slave, the master reports this fault during operation.

Possible causes

Source: MD200 Series Basic AC Drive User Manual P38; MD310 Series General-purpose AC Drive User Manual P233

Series: MD210

Communication fault

AC drive

Meaning: Abnormal host controller operation; Abnormal communication cable; Incorrect settings in communication parameter group FD

Possible causes

Source: MD210 Series AC Drive User Manual, Fault Diagnosis P160

Series: MD280

Communication timeout fault

AC drive

Meaning:

Possible causes

Source: MD280 Series AC Drive User Manual, Fault Record Parameters P70

Series: MD290, MD480, MD480P, MD500, MD500E

Communication fault

AC drive

Meaning:

Possible causes

Source: MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD480 Series Industrial Single-Drive AC Drive User Manual P88; MD480P Series AC Drive User Manual P94; MD500 Series General-Purpose AC Drive Commissioning Manual P122; MD500E Series General-Purpose AC Drive User Manual P235

Series: MD380E

Communication fault

AC drive

Meaning: Host computer is not operating normally; communication cable error; communication expansion card F0-28 setting is incorrect; communication parameter group FD settings are incorrect

Possible causes

Source: MD380E Series AC Drive User Manual, Fault Diagnosis P248

Series: ME320L

Communication fault

elevator controller

Meaning: Encoder fault while stopped

Possible causes

Source: ME320L Integrated Elevator Controller User Manual, Fault Diagnosis P112

Series: NICE2000ft

Reserved

elevator controller

Meaning: Ambient temperature too high; fan damaged; air duct blocked

Possible causes

Source: NICE2000(ft) Door Controller User Manual Fault Diagnosis P69

Series: NICE7000

Current control fault

elevator controller

Meaning: Excessive field current deviation; excessive torque current deviation; torque limit exceeded for too long

Possible causes

Source: NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P57