Inovance Err15 fault code meaning
Inovance / Err15
Series: CAN600
Brake release fault
AC drive
Meaning: The output frequency exceeds the frequency set by F5-07, but the brake release conditions are still not met.
Possible causes
Source: CAN600 Series AC Drive User Manual Fault Diagnosis P89
Series: CL100, CP320, MD290, MD480, MD480P, MD500, MD500E
External equipment fault
AC drive
Meaning:
Possible causes
Source: CL100 Series Integrated Wire Drawing Machine User Manual P35; CP320 Series Air Compressor AC Drive User Manual P49; MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD480 Series Industrial Single-Drive AC Drive User Manual P87; MD480P Series AC Drive User Manual P93; MD500 Series General-Purpose AC Drive Commissioning Manual P122; MD500E Series General-Purpose AC Drive User Manual P235
Series: CS280
External equipment fault
AC drive
Meaning: ◆The STOP key was pressed while keypad run control was not active ◆An external fault signal was received at multifunction terminal DI
Possible causes
Source: CS280 Series Construction Hoist AC Drive User Manual, Fault Diagnosis P109
Series: MD021, MD280, MD300, MD320, MD320N
External fault
AC drive
Meaning:
Possible causes
Source: MD021 Series AC Drive User Manual, Fault Record Parameters P26; MD280 Series AC Drive User Manual, Fault Record Parameters P70; MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77
Series: MD200, MD310
External equipment fault
AC drive
Meaning: Two cases: External terminal normally open fault: the DI terminal should be open, but the AC drive detects that the DI terminal is closed and reports a fault. External terminal normally closed fault: the DI terminal should be closed, but the AC drive detects that the DI terminal is open and reports a fault.
Possible causes
- 1. External fault input via multifunction terminal DI.
- 2. External fault input via the virtual IO function.
Source: MD200 Series Basic AC Drive User Manual P38; MD310 Series General-Purpose AC Drive User Manual P232
Series: MD210, MD380E
External equipment fault
AC drive
Meaning: External fault signal input via multifunction terminal DI; External fault signal input via the virtual IO function
Possible causes
Source: MD210 Series AC Drive User Manual, Fault Diagnosis P160; MD380E Series AC Drive User Manual, Fault Diagnosis P248
Series: ME320L
External fault
elevator controller
Meaning: Elevator controller fault
Possible causes
Source: ME320L Integrated Elevator Controller User Manual, Fault Diagnosis P112
Series: NICE2000ft
Reserved
elevator controller
Meaning: Ambient temperature too high; fan damaged; air duct blocked
Possible causes
Source: NICE2000(ft) Door Controller User Manual Fault Diagnosis P69