Inovance Err14 fault code meaning
Inovance / Err14
Series: CAN600
Module overheat
AC drive
Meaning: Ambient temperature too high; fan damaged; air duct blocked
Possible causes
Source: CAN600 Series AC Drive User Manual Fault Diagnosis P89
Series: CL100
IGBT overheat
AC drive
Meaning:
Possible causes
Source: CL100 Series Integrated Wire Drawing Machine User Manual P35
Series: CP320, MD280
Module overheat
AC drive
Meaning:
Possible causes
Source: CP320 Series Air Compressor AC Drive User Manual P49; MD280 Series AC Drive User Manual, Fault Record Parameters P70
Series: CS280
Module overheat
AC drive
Meaning: ◆Ambient temperature too high ◆Fan damaged ◆Air duct blocked
Possible causes
Source: CS280 Series AC Drive for Construction Hoists User Manual Fault Diagnosis P108
Series: MD021
Heatsink overheat fault
AC drive
Meaning:
Possible causes
Source: MD021 Series AC Drive User Manual, Fault Record Parameters P26
Series: MD200, MD310
AC drive overheat
AC drive
Meaning: An AC drive overheat fault is reported when the heatsink temperature exceeds the overtemperature threshold.
Possible causes
- 1, Ambient temperature too high
- 2, Air duct blocked
- 3, Fan damaged
- 4, Module thermistor damaged
- 5, Damaged product components
Source: MD200 Series Basic AC Drive User Manual P38; MD310 Series General-Purpose AC Drive User Manual P232
Series: MD210, MD380E
Module overheat
AC drive
Meaning: Ambient temperature too high; Blocked air duct; Damaged fan; Damaged module thermistor; Damaged inverter module
Possible causes
Source: MD210 Series AC Drive User Manual, Fault Diagnosis P160; MD380E Series AC Drive User Manual, Fault Diagnosis P248
Series: MD290, MD500
AC drive overheat
AC drive
Meaning:
Possible causes
Source: MD290 Series General-Purpose AC Drive Quick Start Guide P122; MD500 Series General-Purpose AC Drive Commissioning Manual P122
Series: MD300, MD320, MD320N
Heatsink overheat
AC drive
Meaning:
Possible causes
Source: MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77
Series: MD480, MD480P, MD500E
Drive overheat
AC drive
Meaning:
Possible causes
Source: MD480 Series Engineered Single AC Drive User Manual P87; MD480P Series AC Drive User Manual P93; MD500E Series General-Purpose AC Drive User Manual P235
Series: ME320L
Heatsink overheat
elevator controller
Meaning: Ambient temperature too high; fan damaged; air duct blocked
Possible causes
Source: ME320L Integrated Elevator Controller User Manual, Fault Diagnosis P112
Series: NICE1000, NICE2000ft, NICE3000dt, NICE7000
Module overheat
elevator controller
Meaning: Ambient temperature too high; fan damaged; air duct blocked
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P79; NICE2000(ft) Door Controller User Manual, Fault Diagnosis P69; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P120; NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P57