Inovance Err11 fault code meaning
Inovance / Err11
Series: CAN600
Motor overload
AC drive
Meaning: FC-02 Incorrect setting; holding brake circuit error; load too large
Possible causes
Source: CAN600 Series AC Drive User Manual Fault Diagnosis P89
Series: CL100, CP320, MD280, MD290, MD300, MD300A, MD320, MD320N, MD480, MD480P, MD500, MD500E
Motor overload
AC drive
Meaning:
Possible causes
Source: CL100 Series Integrated Wire Drawing Machine User Manual P35; CP320 Series Air Compressor AC Drive User Manual P48; MD280 Series AC Drive User Manual, Fault Record Parameters P70; MD290 Series General-Purpose AC Drive Quick Start Guide P121; MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD300A Series AC Drive User Manual, Fault Record Parameters P44; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77; MD480 Series Industrial Single-Drive AC Drive User Manual P87; MD480P Series AC Drive User Manual P93; MD500 Series General-Purpose AC Drive Commissioning Manual P122; MD500E Series General-Purpose AC Drive User Manual P235
Series: CS280
Motor overload
AC drive
Meaning: ◆Incorrect FC-02 setting ◆Holding brake circuit error ◆Load too large
Possible causes
Source: CS280 Series AC Drive for Construction Hoists User Manual Fault Diagnosis P108
Series: MD200, MD310
Motor overload
AC drive
Meaning: Motor overload is detected when the overload time specified by the motor overload curve is reached.
Possible causes
- 1, Check whether motor protection parameter F9-01 is set appropriately
- 2: Check whether the load is too large or the motor has a locked rotor
Source: MD200 Series Basic AC Drive User Manual P37; MD310 Series General-purpose AC Drive User Manual P231
Series: MD210, MD380E
Motor overload
AC drive
Meaning: Check whether motor protection parameter F9-01 is set appropriately; Check for excessive load or a locked rotor; Undersized AC drive
Possible causes
Source: MD210 Series AC Drive User Manual, Fault Diagnosis P160; MD380E Series AC Drive User Manual, Fault Diagnosis P248
Series: ME320L
Motor overload
elevator controller
Meaning: Improper F9-01 setting; holding brake circuit error; load too large
Possible causes
Source: ME320L Integrated Elevator Controller User Manual, Fault Diagnosis P112
Series: NICE1000, NICE2000ft, NICE3000dt, NICE7000
Motor overload
elevator controller
Meaning: FC-02 Incorrect setting; holding brake circuit error; load too large
Possible causes
Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P79; NICE2000(ft) Door Controller User Manual, Fault Diagnosis P69; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P119; NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P57