Inovance Err07 fault code meaning
Inovance / Err07
Series: CAN600
Overvoltage at constant speed
AC drive
Meaning: Input voltage too high; selected braking resistor resistance too large, or braking unit error
Possible causes
Source: CAN600 Series AC Drive User Manual, Fault Diagnosis P88
Series: CL100, CP320, MD021, MD280, MD290, MD300, MD300A, MD320, MD320N, MD480, MD480P, MD500E
Overvoltage at constant speed
AC drive
Meaning:
Possible causes
Source: CL100 Series Integrated Wire Drawing Machine User Manual P35; CP320 Series AC Drive for Air Compressors User Manual P48; MD021 Series AC Drive User Manual, Fault Record Parameters P26; MD280 Series AC Drive User Manual, Fault Record Parameters P70; MD290 Series General-Purpose AC Drive Quick Start Guide P121; MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD300A Series AC Drive User Manual, Fault Record Parameters P44; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77; MD480 Series Engineered Single AC Drive User Manual P87; MD480P Series AC Drive User Manual P93; MD500E Series General-Purpose AC Drive User Manual P234
Series: CS280
Overvoltage at constant speed
AC drive
Meaning: ◆Input voltage too high ◆Selected braking resistor resistance too large, or braking unit error
Possible causes
Source: CS280 Series AC Drive for Construction Hoists User Manual Fault Diagnosis P108
Series: MD200, MD310
Overvoltage at constant speed
AC drive
Meaning: At constant speed, the DC bus voltage exceeds the overvoltage threshold set by A5-09, in units of V.
Possible causes
- 1: Inappropriate overvoltage suppression setting
- 2, An external force drives the motor during operation
Source: MD200 Series Basic AC Drive User Manual P37; MD310 Series General-Purpose AC Drive User Manual P229
Series: MD210, MD380E
Overvoltage at constant speed
AC drive
Meaning: High input voltage; External force driving the motor during operation
Possible causes
Source: MD210 Series AC Drive User Manual, Fault Diagnosis P160; MD380E Series AC Drive User Manual, Fault Diagnosis P247
Series: ME320L, NICE1000, NICE2000ft, NICE3000dt, NICE7000
Overvoltage at constant speed
elevator controller
Meaning: Input voltage too high; selected braking resistor resistance too large, or braking unit error
Possible causes
Source: ME320L Integrated Elevator Controller User Manual, Fault Diagnosis P112; NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P79; NICE2000(ft) Door Controller User Manual, Fault Diagnosis P68; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P119; NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P56