Inovance Err06 fault code meaning

Inovance / Err06

Series: CAN600

Overvoltage during deceleration

AC drive

Meaning: Input voltage too high; braking resistor resistance too large or braking unit error; deceleration curve too steep

Possible causes

Source: CAN600 Series AC Drive User Manual, Fault Diagnosis P88

Series: CL100, CP320, MD021, MD280, MD290, MD300, MD300A, MD320, MD320N, MD480, MD480P, MD500E

Overvoltage during deceleration

AC drive

Meaning:

Possible causes

Source: CL100 Series Integrated Wire Drawing Machine User Manual P35; CP320 Series Air Compressor AC Drive User Manual P48; MD021 Series AC Drive User Manual, Fault Record Parameters P26; MD280 Series AC Drive User Manual, Fault Record Parameters P70; MD290 Series General-Purpose AC Drive Quick Start Guide P121; MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD300A Series AC Drive User Manual, Fault Record Parameters P44; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77; MD480 Series Industrial Single-Drive AC Drive User Manual P86; MD480P Series AC Drive User Manual P92; MD500E Series General-Purpose AC Drive User Manual P234

Series: CS280

Overvoltage during deceleration

AC drive

Meaning: ◆Input voltage too high ◆Selected braking resistor resistance too large, or braking unit error ◆Deceleration curve too steep

Possible causes

Source: CS280 Series AC Drive for Construction Hoists User Manual Fault Diagnosis P108

Series: MD200, MD310

Overvoltage during deceleration

AC drive

Meaning: During deceleration, the DC bus voltage exceeds the overvoltage threshold set by A5-09, in units of V.

Possible causes

Source: MD200 Series Basic AC Drive User Manual P36; MD310 Series General-Purpose AC Drive User Manual P229

Series: MD210

Overvoltage during deceleration

AC drive

Meaning: High input voltage; External force driving the motor during deceleration; Deceleration time too short; No braking resistor installed

Possible causes

Source: MD210 Series AC Drive User Manual, Fault Diagnosis P160

Series: MD380E

Overvoltage during deceleration

AC drive

Meaning: High input voltage; an external force drives the motor during deceleration; deceleration time is too short; no braking unit or braking resistor installed

Possible causes

Source: MD380E Series AC Drive User Manual, Fault Diagnosis P247

Series: NICE1000, NICE2000ft, NICE3000dt, NICE7000

Overvoltage during deceleration

elevator controller

Meaning: Input voltage too high; braking resistor resistance too large or braking unit error; deceleration curve too steep

Possible causes

Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P79; NICE2000(ft) Door Controller User Manual, Fault Diagnosis P68; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P119; NICE7000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P56