Inovance Err01 fault code meaning

Inovance / Err01

Series: CAN600

Inverter unit protection

AC drive

Meaning: Ground fault or short circuit at the main circuit output; traction motor cable too long; operating environment too hot; loose internal drive wiring

Possible causes

Source: CAN600 Series AC Drive User Manual, Fault Diagnosis P88

Series: MD021, MD300, MD300A, MD320, MD320N

Inverter unit protection

AC drive

Meaning:

Possible causes

Source: MD021 Series AC Drive User Manual, Fault Record Parameters P25; MD300(MD300N) Series AC Drive User Manual, Fault Record Parameters P61; MD300A Series AC Drive User Manual, Fault Record Parameters P44; MD320 Series General-Purpose AC Drive User Manual, Fault Record Parameters P73; MD320(MD320N) Series AC Drive User Manual, Fault Record Parameters P77

Series: MD380E

Inverter unit protection

AC drive

Meaning: Short circuit in the AC drive output circuit; wiring between the motor and AC drive is too long; module overheat; loose internal wiring in the AC drive; main control board error; driver board error; inverter module error

Possible causes

Source: MD380E Series AC Drive User Manual, Fault Diagnosis P247

Series: NICE1000, NICE2000ft, NICE3000dt

Inverter unit protection

elevator controller

Meaning: Ground fault or short circuit at the main circuit output; traction machine cables too long; operating environment too hot; loose internal controller wiring

Possible causes

Source: NICE1000 Series Integrated Elevator Controller User Manual, Fault Diagnosis P78; NICE2000(ft) Door Controller User Manual, Fault Diagnosis P68; NICE3000(dt) Integrated Elevator Controller User Manual, Fault Diagnosis P118