Inovance Er142 fault code meaning
Inovance / Er142
Series: CS200, CS710
Brake applied (holding) fault
AC drive
Meaning:
Possible causes
- After the brake curve is enabled via b6.00 and the brake feedback function is enabled via b6.08
- 1, Hardware fault at the brake applied (holding) feedback signal input.
- 2, The brake requires time to become fully applied, but the detection time set by b6.06 is too short.
Source: CS200 Crane AC Drive User Manual P115; CS710 Crane AC Drive User Manual P164