Inovance Er107 fault code meaning
Inovance / Er107
Series: CS290, CS300, CS710
Overvoltage at constant speed
AC drive
Meaning:
Possible causes
- High input voltage
- An external force drives the motor during run
Source: CS290 Crane AC Drive User Manual P68; CS300 Crane AC Drive User Manual P113; CS710 Crane AC Drive User Manual P162