Inovance Er04 fault code meaning

Inovance / Er04

Series: NICE900

Overcurrent at constant speed

elevator controller

Meaning: Main circuit output ground fault or short circuit; check whether motor parameter tuning has been performed; load too large; excessive interference affecting the rotary encoder

Possible causes

Source: NICE900 Door Controller User Manual Fault Diagnosis P67