Inovance EE10.1 fault code meaning
Inovance / EE10.1
Series: SV630N
SM2 configuration error
servo drive
Meaning:
Possible causes
Source: SV630N Series Servo User Manual P533
Series: SV670N-LK, SV670N-PTC
SM2 configuration error
servo drive
Meaning: 1.PDO The mapped object dictionary index exceeds the configured maximum (0x1600~0x170A); 2.SM2 when not enabled, the lengths of SM and RxPDO are not equal to 0; 3.RxPDO length mismatch; 4. is not in the write direction; 5. in the preop state, the address of RxPDO is outside the configured address range (maximum and minimum addresses), or when not in the preop state, the address of SM2 equals the start address of RxPDO; 6.SM2 overlaps the memory of the adjacent SM1 or SM3.
Possible causes
- 1.Due to a master configuration error, 2.the slave XMLfile is incorrect.
Source: SV670N-LK Series Servo User Manual P634; SV670N-PTC Series Servo User Manual P611
Series: SV670NS-INT
SM2 configuration error
servo drive
Meaning: 1.PDO mapped object dictionary index exceeds the configured maximum (0x1600~0x170A). 2.SM2 When not enabled, the lengths of SM and RxPDO are not equal to 0. 3.RxPDO length mismatch. 4. is not in the write direction. 5. In the preop status, the address of RxPDO is outside the configured address range (maximum and minimum addresses), or when not in the preop status, the address of SM2 equals the start address of RxPDO. 6.SM2 overlaps the memory of the adjacent SM1 or SM3.
Possible causes
- 1.Due to a master configuration error, 2.the slave XMLfile is incorrect.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P944