Inovance EE08.0 fault code meaning
Inovance / EE08.0
Series: STD60N-XH, STD60N
Synchronization signal loss
stepper drive
Meaning: When the EtherCAT network is in the OP state, synchronization signal SYNC is disabled.
Possible causes
- 1. Slave receive error during synchronous communication
Source: STD60N-XH Series Stepper User Manual P286; STD60N Series Stepper User Manual P389
Series: SV630N
Synchronization signal loss
servo drive
Meaning:
Possible causes
Source: SV630N Series Servo User Manual P532
Series: SV670N-LK, SV670N-PTC, SV670NS-INT
Synchronization signal loss
servo drive
Meaning: When the EtherCAT network is in the OP state, synchronization signal SYNC is disabled.
Possible causes
- 1. The synchronization signal is not generated due to a hardware issue.
- 2.Slave receive error during synchronous communication
- 3.Master send error during synchronous communication
- 4.The network switches from OP to a state other than OP while the servo is enabled
Source: SV670N-LK Series Servo User Manual P634; SV670N-PTC Series Servo User Manual P611; SV670NS-INT Series Servo User Manual (SIL2 Safety Edition) P944