Inovance EB03.2 fault code meaning
Inovance / EB03.2
Series: SV630A, SV630C, SV630P, SV660A, SVD60C
Electronic gear ratio setting out of range - second electronic gear ratio
servo drive
Meaning:
Possible causes
Source: SV630A Series Servo User Manual P529; SV630C Series Servo User Manual P536; SV630P Series Servo User Manual P527; SV660A Series Servo User Manual P588; SVD60C Series Servo Function Manual P641
Series: SV670N-LK, SV670N-PTC, SV670NS-INT
Electronic gear ratio setting out of range - second electronic gear ratio
servo drive
Meaning: The second electronic gear ratio exceeds the specified limits: (0.001~4000 × encoder resolution ÷ 10000).
Possible causes
- The second electronic gear ratio exceeds the maximum gear ratio or is below the minimum gear ratio.
Source: SV670N-LK Series Servo User Manual P634; SV670N-PTC Series Servo User Manual P611; SV670NS-INT Series Servo User Manual (SIL2 Safety Edition) P944