Inovance EB00.1 fault code meaning
Inovance / EB00.1
Series: STD60N-XH, STD60N
Position deviation overflow
stepper drive
Meaning: Excessive position deviation calculated internally by the servo drive.
Possible causes
- 1. Drive UVW output phase loss or incorrect phase sequence connection
Source: STD60N-XH Series Stepper User Manual P286; STD60N Series Stepper User Manual P389
Series: SV630A, SV630C, SV630N, SV630P, SV660A, SVD60C
Position deviation overflow
servo drive
Meaning:
Possible causes
Source: SV630A Series Servo User Manual P529; SV630C Series Servo User Manual P536; SV630N Series Servo User Manual P532; SV630P Series Servo User Manual P527; SV660A Series Servo User Manual P588; SVD60C Series Servo Function Manual P641
Series: SV670N-LK, SV670N-PTC, SV670NS-INT
Position deviation overflow
servo drive
Meaning: Excessive position deviation calculated internally by the servo drive.
Possible causes
- 1.Servo drive UVWoutput phase loss or incorrect phase sequence wiring.
- 2.Servo drive UVW output open or encoder open
- 3.Locked rotor due to mechanical factors.
- 4.Servo drive gain is low.
- 5. position command increment is too large.
- 6.Fault value 6065h is too small for the operating conditions
- 7.Servo drive/motor fault.
Source: SV670N-LK Series Servo User Manual P634; SV670N-PTC Series Servo User Manual P611; SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P943