Inovance E938.0 fault code meaning
Inovance / E938.0
Series: STD60N-XH, STD60N
Incorrect motor power cable phase connection
stepper drive
Meaning: At least two motor power phases are connected incorrectly
Possible causes
- Incorrect motor power cable connection
Source: STD60N-XH Series Stepper User Manual P285; STD60N Series Stepper User Manual P389