Inovance E845.0 fault code meaning
Inovance / E845.0
Series: SV670N-LK
Force sensor signal polarity reversed
servo drive
Meaning: 1.Force sensor signal wires are reversed; 2.the force sensor output range includes negative voltage
Possible causes
- 1.Force sensor signal wires are reversed; 2.the force sensor output range includes negative voltage
Source: SV670N-LK Series Servo User Manual P634