Inovance E751.4 fault code meaning
Inovance / E751.4
Series: SV670NS-INT
Safety MCU standard encoder data decoding error
servo drive
Meaning: 1.Safety MCU communication timeout when receiving standard encoder data. 2.Safety MCU checksum error in received standard encoder data
Possible causes
- Safety MCU communication timeout with the encoder
- Safety MCU checksum error in received encoder data
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P940