Inovance E750.7 fault code meaning
Inovance / E750.7
Series: SV670NS-INT
Encoder internal SPI communication error; no response from the slave
servo drive
Meaning: The slave fails to receive the master's command word normally, or the master fails to receive the slave's response frame normally.
Possible causes
- Board-level communication interference causes internal CRC checksum failure, peripheral errors, etc.
Source: SV670NS-INT Series Servo User Manual (SIL2 Safety Version) P940
Series: SV680F-INT, SV680F, SV680LN-PLUS, SV680LP-PLUS, SV680N-INT, SV680P-INT
Encoder internal SPI communication error; no response from the slave
servo drive
Meaning:
Possible causes
Source: SV680F-INT Series Servo Function Manual P639; SV680F Series Servo User Manual P786; SV680LN-PLUS Direct-Drive Motor Servo User Manual P873; SV680LP-PLUS Direct-Drive Motor Servo User Manual P779; SV680N-INT Series Servo Function Manual P917; SV680P-INT Series Servo Function Manual P821